OML Model # 2378H231 Radiated Harmonic Emissions Testing Kit

(A pdf version is available.)

Harmonic and Frequency vs. OML Mixer Model No.

Signal x2   x3   x4   x5   x6   x7   x8  
GHz   Mixer #   Mixer #   Mixer #   Mixer #   Mixer #   Mixer #   Mixer #
23 46 M19HW 69 M12HW 92 M08HW 115 M08HW 138 M08HW 161 M05HW 184 M05HW
24 48 " 72 " 96 " 120 " 144 M05HW 168 " 192 "
25 50 " 75 " 100 " 125 " 150 " 175 " 200 "
26 52 " 78 " 104 " 130 " 156 " 182 " 208 "
27 54 " 81 " 108 " 135 M08HW 162 " 189 " 216 M05HW
28 56 " 84 " 112 " 140 --------- 168 " 196 " 224 M03HW
29 58 M19HW 87 M12HW 116 " 145 M05HW 174 " 203 " 232 M03HW
30 60 --------- 90 --------- 120 " 150 " 180 " 210 "    
31 62 M12HW 93 M08HW 124 " 155 " 186 " 217 M05HW    
32 64 " 96 " 128 " 160 " 192 " 224 M03HW    
33 66 " 99 " 132 " 165 " 198 " 231 M03HW    
34 68 " 102 " 136 M08HW 170 " 204 "        
35 70 " 105 " 140 --------- 175 " 210 "        
36 72 " 108 " 144 M05HW 180 " 216 M05HW        
37 74 " 111 " 148 " 185 " 222 M03HW        
38 76 " 114 " 152 " 190 " 228 M03HW        
39 78 " 117 " 156 " 195 "            
40 80 " 120 " 160 " 200 "            
41 82 " 123 " 164 " 205 "            
42 84 " 126 " 168 " 210 "            
43 86 " 129 " 172 " 215 M05HW            
44 88 M12HW 132 " 176 " 220 ---------            
45 90 -------- 135 " 180 " 225 M03HW            
46 92 M08HW 138 M08HW 184 " 230 M03HW            
47 94 " 141 M05HW 188 "                
48 96 " 144 " 192 "                
49 98 " 147 " 196 "                
50 100 " 150 " 200 "                
51 102 " 153 " 204 "                
52 104 " 156 " 208 "                
53 106 " 159 " 212 "                
54 108 " 162 " 216 M05HW                
55 110 " 165 " 220 ---------                
56 112 " 168 " 224 M03HW                
57 114 " 171 " 228 "                
58 116 " 174 " 232 M03HW                
59 118 " 177 "                    
60 120 " 180 "                    
61 122 " 183 "     FCC Spurious Emissions Suppression Testing Requirements
62 124 " 186 "     Signal <10 GHz           the lower of the 10th harmonic or 40 GHz
63 126 " 189 "     Signal 10 to 30 GHz    the lower of the 5th harmonic or 100 GHz
64 128 " 192 "     Signal >30 GHz            the lower of the 5th harmonic or 200 GHz
65 130 " 195 "     Signal 76 to 77 GHz     to 231 GHz        
66 132 " 198 "                    
67 134 " 201 "     OML Mixer Model # vs Frequency Coverage    
68 136 " 204 "     M19HW = 40 to 60 GHz          Waveguide cutoff = 31.41 GHz
69 138 M08HW 207 "     M12HW = 60 to 90 GHz          Waveguide cutoff = 48.35 GHz
70 140 --------- 210 "     M08HW = 90 to 140 GHz        Waveguide cutoff = 73.84 GHz
71 142 M05HW 213 "     M05HW = 140 to 220 GHz      Waveguide cutoff = 115.75 GHz
72 144 " 216 "     M03HW = 220 to 325 GHz      Waveguide cutoff = 173.28 GHz
73 146 " 219 M05HW                    
74 148 " 222 M03HW     Frequency coverage of a mixer type extends to the line (---------).
75 150 " 225 "                    
76 152 " 228 "                    
77 154 " 231 M03HW                    
78 156 M05HW                        

Updated 1/26/2000

300 Digital Drive, · Morgan Hill, CA 95037
Tel. (408) 779-2698 · FAX: (408) 778-0491 · email: info@omlinc.com

| Home | Introduction | Vector | Sources | Scalar | Spectrum | Power |
© 1999-2006 OML, Inc. (Oleson Microwave Labs.) All Rights Reserved.